TIMANTTI 3 Primer







Water-borne acrylate dispersion primer for walls and ceilings indoors. Mildew-resistant.
Finish: full-matt.
The product has been classified to Group M1 in Emission Classification of building materials.
For priming unpainted concrete, plaster, stopper, brick and building board surfaces.
TIMANTTI 3 can be used as an adhesion primer for wall and ceiling surfaces previously painted with alkyd or dispersion paints. Also suitable for priming surfaces that are to be wallpapered or to which a stick-on wall covering (e.g. a non-woven wallpaper) is attached.
TIMANTTI 3 can also be applied on galvanized sheet metal surfaces, such as air condition pipes.
Technical Data | |
---|---|
Solids | About 39 % by volume |
Volatile organic compound (VOC) | EU VOC limit value (kat A/g): 30 g/l. The product's VOC: max. 30 g/l. |
Practical spreading rate | 4 - 8 m²/l depending on the absorbency and coarseness of the substrate |
Density | abt. 1.6 g/ml |
Drying time +23 °C, the relative air humidity 50 % - dust free - overcoatable - fit for wallpapering | after ½ hour after 1 hour after 24 hours The drying will be slowed down if the air is cool and/or humid. |
Thinner, clean up | Water. Wash the equipment immediately after use with detergent and warm water. |
Finish | Full-matt |
Colours | White. Can be tinted with tinting pastes to light shades according to the Interior Colour Cards. The colour accuracy is not complete. Off-white T1327 (TC-8168) |
Washability and wear resistance | Wet scrub resistance, class 2 according to EN 13300 (ISO 11998). |
Packages (availability varies by country) | White: 0,9 L, 2,7 L, 9 L, 18 L Off-white T1327 (TC-8168): 18 L |
SAFETY MARKINGS | See Safety Data Sheet. |
Direction for Use | |
---|---|
Surface preparation | Clean the surface from dirt and dust. Wash previously painted, dirty surfaces with RENSA SUPER paint cleaner. Matt down hard or gloss surfaces by sanding and thereafter remove the dust. For smoothing of irregularities in the surface choose a suitable filler from the SILORA series. The dried filler is sanded down and the dust removed. Steel surfaces are primed with FERREX AQUA Anticorrosive paint. TIMANTTI 3 is a water-borne paint. Coatings, which are not waterproof, such as old unpainted ceiling stopper or glue paint coats, must be removed before applying TIMANTTI 3. Alternatively FUTURA 3 adhesion primer can be used as an insulation primer. |
Application | Before use stir the paint thoroughly. The paint can be diluted with water, if required, but dilution may impair the coverage of the paint. Apply by roller, spray or brush. Recommended nozzle size for airless spray is 0.017 - 0.021''. |
Top coating | Surfaces primed with TIMANTTI 3 are top coated with top coats from TIMANTTI series. For top coating can also be used other Teknos´ interior paints which otherwise suit the object in question and the chosen coating system. TIMANTTI 3 is white and full-matt and hence can be used also as a top coat e.g. on ceilings. |
Application conditions | The surface to be painted must be dry. During the application and drying period the temperature of the ambient air, the surface and the paint shall be above +5 °C and the relative air humidity below 80 %. Drying is faster in low air humidity and/or above + 21 °C. Application will be easier if air is humidified and/or temperature is lowered in the working space. Ventilation after the painting will quicken the drying. |
Storage | Must not freeze. |